SDM Microscopes

The Kaps SDM examination microscope is designed for ENT specialists who are unwilling to compromise on optical quality and are looking for a high-quality, easy-maintenance microscope for carrying out examinations.

Kaps SDM is the perfect entry model and boasts a sensational price-performance ratio.

We have focused on the main features impacting medical examinations, and have combined tried-and-true Kaps optics with bright LED illumination and high operating comfort.

Kaps optics provides crystal-clear images and high-resolution details in natural colors (apochromatic optics).

The LEDone illumination system offers a number of extremely positive product characteristics that score over conventional halogen light sources:

  • Fatigue-free detailed working in daylight quality
  • Absolutely silent and vibration-free
  • Long life (30,000 hours)
  • Low energy requirement
Technical Data
Illumination LEDone illumination unit
Objective Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lenses f = 200 mm and f = 250 mm with integrated focusing (14 mm)
Binocular tubes Straight tube f = 125 mm or f = 159 mm
Eyepieces Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment)
Magnification 3-step magnification changer, 5-step magnification changer at additional cost
Fine focussing Manual fine focusing 40 mm (optional)
Video camera Adaptation for C-mount video cameras by beam splitter and TV tube
Integrated endoscope adapter For directly adapting existing endoscope cameras
Made in Germany by Karl Kaps GmbH & CO KG.

SOM® Microscopes

SOM® 22 – for Wall Mounting and Use with Examination Units The SOM® microscope is available in three versions:
Technical Data
Illumination Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional
Objective Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm)
Binocular tubes Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210°
Eyepieces Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment)
Magnification 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6
Fine focussing Binocular or monocular
Video camera Adaptation of C-mount video cameras via beam splitter and TV tube
Integrated video camera (Vision) For direct adaptation for existing endoscopic cameras
Iris diaphragm, green filter, spot illumination Optional
Made in Germany by Karl Kaps GmbH & CO KG.

SOM® 32 – for Ceiling Mounting

Technical Data
Illumination Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional
Objective Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm)
Binocular tubes Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210°
Eyepieces Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment)
Magnification 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6
Fine focussing Manual fine focussing 40 mm (optional)
Secondary viewer Binocular or monocular
Video camera Adaptation of C-mount video cameras via beam splitter and TV tube
Integrated video camera (Vision) For direct adaptation for existing endoscopic cameras
Iris diaphragm, green filter, spot illumination Optional
Made in Germany by Karl Kaps GmbH & CO KG.

SOM® 62 – on a Mobile Stand

Technical Data
Illumination Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination optional
Objective Changeable lenses from 200 mm to 400 mm in steps of 50 mm Lens f = 200 mm and f = 250 mm with integrated focussing (14 mm)
Binocular tubes Straight tube f = 125 mm or f = 159 mm, on request swivel tube f = 182 mm 0 – 210°
Eyepieces Eyepieces WF 12.5 x V or WF 10 x V (with diopter adjustment)
Magnification 3-step magnification changer, 5-step magnification changer or manual zoom 1 – 6
Fine focussing Manual fine focussing 40 mm (optional)
Secondary viewer Binocular or monocular
Video camera Adaptation of C-mount video cameras via beam splitter and TV tube
Integrated video camera (Vision) For direct adaptation for existing endoscopic cameras
Iris diaphragm, green filter, spot illumination Optional
Made in Germany by Karl Kaps GmbH & CO KG.

SOM® Operating Microscopes

Kaps Pro ENT High End Manual
Binocular tubes Straight tube f = 125 mm Binocular Swivel Tube 0-210°, f = 182 (optional)
Objective F = 250 mm
Eyepieces WF 12.5 x V with diopter adjustment WF 10 x V with diopter adjustment (optional) Other on request
Magnification -step apochromatic magnification changer
Filter Swing-in green filter
Illumination Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination (optional)
Handles Ergonomic handle, bilateral, 360°, adjustable with disengage knob
Made in Germany by Karl Kaps GmbH & CO KG.

Kaps PRO ENT motorized

TECHNICAL DATA
Binocular tubes Straight tube f = 125 mm Binocular Swivel Tube 0-210°, f = 182 (optional)
Objective F = 250 mm
Eyepieces WF 12.5 x V with diopter adjustment WF 10 x V with diopter adjustment (optional) Other on request
Magnification 1:6 Zoom
Filter Swing-in green filter
Illumination Coaxial cold light illumination (15 V / 150 W) with spare bulb LED illumination (optional)
Handles Ergonomic handle, bilateral, 360°, adjustable with disengage knob
Made in Germany by Karl Kaps GmbH & CO KG.

ENT Workstations

G35

G35 ENT Unit is constitute of two parts: operation table and mini writing table, G35 ENT Unit is able to attach various of medical equipment, like ENT patient chair, endoscope, CCD camera, cold light source, medical monitor, etc. By it’s simple design and small size, perfectly using the clinic space. The major material is made of ABS, table top is made of top white marble glass, anti-infection and easy for cleaning.

Technical parameter:
  • Power Supply: AC220-240V, 50Hz~60Hz
  • Power: 800W
  • Positive pressure: 0-0.26Mpa (adjustable), 450W
  • Suction range: 0-800mmHg (adjustable), 450W, silent suction pump: 70 L/min;
  • Spray volume: 3-9ml/min, spray angle: >20°,
  • Pre-heating device: 450W, 0-180 seconds(adjustable)
  • LED Cold light source: 12V, 10W, 5000-10000K
  • LED Operating headlight: 3W, cold light, adjustable spot light
Technical Data
Made in Germany by Karl Kaps GmbH & CO KG.

ENT Workstations

G65

G65 ENT Unit is constitute of operation table and writing table. The main frame is made of durable steel, non rusting, long lasting. The metal frame was surrounded by the ABS appearance. The table top is made of top white marble glass, it’s anti-infection and easy for cleaning.

G65 ENT Unit have two air storage tank. Compressor and vacuum pump will start working automatically after power on and stop working automatically when storage tank are full of air.

Negative system has 10 seconds delay function after putting suction gun back to original position. Warning system will alarm when the dirt reach to limit warning. Vacuum gauge, bacterial filters, 1.5 liters liquid container and effective device to prevent overflow.

Compressed air system continuously adjustable from 0.1 to 4 bars for spray, spray liquid with autoclavable nozzle for cleaning. Inbuilt motor suction unit with capacity of 70 liters per minute. Compressor and vacuum pump will automatically shut down after working continuously for more than 20 minutes. Stainless steel tank for compressed air of capacity of 1.5, Compressor unit completely separate from suction unit. Handle for compressed air have a regulation valve.

Laryngoscope pre-heater device, heating system to heat the instruments. 38℃ constantly warm water rinsing system.

Technical parameter:
  • Power Supply: AC220-240V,50Hz~60Hz, Power: 800W;
  • Spray pressure: 0-0.35Mpa (adjustable), 450W;
  • Spray volume: 3-9ml/min, spray angle: >20°;
  • Pre-heating device: 450W, heating: 0-180 seconds(adjustable);
  • Suction range: > 0~1000mmHg(adjustable), 450W(adjustable), silent suction pump: 70 L/min, suction bottle 2500cc;
  • LED Cold light source: 12V, 10W, 5000-10000K;
  • LED Operating headlight: 3W, cold light,
  • adjustable spot light
Technical Data
Made in Germany by Karl Kaps GmbH & CO KG.

ENT Workstations

G30

G30 Luxury ENT Treatment Unit with patient chair
  • Power Supply: AC220-240V, 50Hz~60Hz;
  • Power: 800W;
  • Positive Pressure: 2 . 5kg / cm 2 (adjustable), 80W;
  • Suction range: 0 – 850 mm H g (ma x), 350W;
  • Spray volume: 6.5ml/min, 0-0.28Mpa;
  • Pre heating device: 450w, 0-180 seconds(adjustable).

Electric Patient Chair

G011 Standard Electric ENT patient chair

Technical parameters:
  • Voltage:AC220-240V, 50-60HZ
  • Power:230W(max)and low power consumption, energy saving.
  • Under weight pressure:250KGS(max)
  • Seat height adjustment: 530mm (minimum)-650mm(maximum)
  • Backrest adjustable angle: range from degree 90-135
  • Pillow flex:100mm (folding, detachable)
  • Size: 790x750x1335 (mm)

G010 Luxury ENT patient chair

Technical parameters:
  • Voltage: AC220-240V, 50-60HZ
  • Motorized and ergonomically designed with two motors controlling up/down, stand/lie movement.
  • The backrest is able to backward 90 degree, the chair could be complete rotation 360 degrees with locking device, foot switch can adjustment the chair height and movement.
  • Power: 230W(max)and low power consumption, energy saving. Weight pressure: 250KG(max).
  • Motorized lifting device, chair height adjustment: 530mm(min)- 680mm (max).
  • Comfortably padded and folded back for enabling easy sitting of overweight and handicapped patient.
  • Armrest and footrest be synchronized with backrest movement, Backrest adjustable and can be made to incline 10 degree forward to vertical position and backward can completely to a horizontal position and can be rolled back.
  • Electric motor -2/piecesPillow flex: 100mm (folding, detachable)

ENT Surgical Head Light

B7 LED Operating Headlight

Techinical Parameter
  • LED bulb: 5w ;
  • Colour temperature: 6000k, pure white;
  • Bulb life time: 20,000 hours;
  • The light spot facular size adjustable; rang from 6mm to 65mm at working distance 25cm.
  • The brightness 95000lux, and adjustable;
  • Lithium battery capacity: 2600mAh ×4 pcs;
  • Continuous working time: 10 hours (Two battery packs each one is 5 hours replaceable);
  • Weight of the light head: 20g
  • AC adaptor charger: Input 90-240V/ DC: 3.7V;
  • The headband is comfortable for wearing, more dapper, it is easy to adjust size.

FD-B8 LED Operating headlight for medical examination

Specification:
  • LED bulb: 3w ;
  • Colour temperature: 6000k pure white;
  • The light spot facular size adjustable;
  • The brightness 48000lux, and adjustable;
  • Lithium battery capacity: 5200mAh (2600mAh each, 2 pcs);
  • Continuous working time: 10 hours (Two battery packs each one is 5 hours replaceable);
  • Bulb life time: 20,000 hours;
  • Weight of the light head: 68g
  • AC adaptor charger: Input 100-240V/ Output 4.2V 1A;
  • The headband is comfortable for wearing, more dapper, it can adjust the size easiest.

Medical Endoscope CCD Camera &LED Light Source (FD-GW600)

Specification:
  • Camera: Horizontal resolution: 700 lines;
  • Input power: 35VA;
  • Power supply: AC 220V 50Hz;
  • Effective pixel: N:768(H)*494(V);
  • SNR: ≥50dB
  • Anti-interference
  • Video output: BNC*2, VGA*1
  • White balance: Automatic /Manual
  • LED light source:
  • Brightness: 190,000Lux
  • Color temperature: ≥6500k
  • Light image temperature: ≤80℃
  • Digital display
Technical data:
  • 21″ HD LCD screen
  • Dimension ratio: 16:9
  • Input signal: DVI,VGA,S-VIDEO,CVBS
  • Power supply: AC100~240V 50/60HZ
  • Power: 40VA,
  • Horizontal Resolution:1280×1024
Technical data:
  • 15″ LCD screen, Dimension ratio: 4:3
  • Input signal: DVI , VGA,S-VIDEO,CVBS
  • Power supply:AC100~240V 50/60HZ
  • Power:40VA
  • Horizontal Resolution: 1024×768

Medical Full HD Endoscopy Camera System (A2500 Series)

Technical Parameter:
  • Sensor: high sensitive 1/3″ CCD camera, SONY CCD: 1280 P×720 P
  • Output Definition: ≥900 line(Measurement According to ISO 12233 Photography
  • Standard Test Card)
  • Zoom coupler: F18, F20, F22, F24, F28, F32, F35mm, F15-25mm, F18-35mm,
  • Stryker Standard, Olympus Standard, Pentax Standard(selectable),
  • Scanning mode: Progressive
  • Image format: 16:9, Minimum illumination: 0.2 lux, Signal noise ratio: 60db
  • Video output interface: CVBS, HDMI, DVI, HD-SDI
  • 2 Pre-programmed camera head button functions (Freeze & W.B
  • & Rotate & hold/pause the image), Camera cable length: 3.25m
  • Light guide cable: 2meter, standard diameter

ENT Operating Microscope (FD-A101 Series)

Specification:
  • The 3 steps ENT examination microscope with integrated mechanical support arm,
  • high transmission, high performance LED illumination in the microscope head.
  • 3-step magnification adjustment: 0.6x, 1.0x, 1.6x;
  • F=200mm & F=300mm, two objectives with different focusing distance;
  • Integrated, high performance white-light-LED Luminescence: min. 12 klux (200 mm), 30 klux (400 mm);
  • High brightness 10W LED illumination, Color temperature: 4000 K;
  • Total Magnification: 3x-12x; wide-field eyepiece 17.3x magnification;
  • External 1080PHA Camera with 1920X1080@60Hz resolution;
  • Color filter green, with pivot mechanism;
  • Optimized stereo effect by 24 mm stereo basis;
  • The ENT microscope could mounting with main ENT unit.

ENT endoscope ccd camera & LED light source

Technical data:
  • Camera: Horizontal resolution: 700 lines
  • Input power: 35VA
  • Power supply: AC 220V 50Hz
  • Effective pixel: N:795(H)*596(V), SNR: ≥50dB
  • Anti-interference; Port: USB, BNC
  • White balance: Automatic /Manual
  • LED light source: power: 35watt; Color temperature: ≥6500k; Light image temperature: ≤80℃
  • Standard monitor
  • HD recorder

ENT Treatment Unit

FUTERENT III

Derived from a long line of designs, the FUTURENT® ENT treatment unit is ergonomically designed to simplify ENT OPD procedures, vastly improve efficiency and reduce user fatigue in the ENT consulting / treatment room. Touch-screen operation, hygienic materials, carefully selected finishes and other elements are combined to form the basis of an efficient, durable and patient-friendly setting. Modern electronics help optimize efficiency and minimize downtime. Modular furniture can be added to the FUTURENT® in accordance with particular requirements, available space and budget to create an ergonomic ENT suite. This further improves efficiency and gives the consulting / treatment room a professional ambience.

  • High-tech control console for easy touch operation
  • Superior ergonomic design for reduced user fatigue
  • Maximum instrument and accessory storage space
  • Vast choice of integrated functions
  • No knobs and buttons to hamper cleaning
  • Custom made in accordance with specific requirements
INTEGRATED FUNCTIONS BY CHOICE

The Futurent® can be equipped with a wide selection of integrated functions to accommodate specific requirements and budget.

  • Suction system (automatically activated)
  • Rinsing facility for hose and secretion receptacle
  • Automatic secretion discharge
  • Small basin with irrigation for clearing blocked suction tubes
  • Compressed air c/w 3 atomizers (automatically activated)
  • LED or halogen fibre optic light source for rigid and flexible endoscopes (automatically activated)
  • LED or halogen fibre optic light source with switchable hook for examination headlight
  • Cordless examination headlight with battery charger integrated in the treatment unit
  • Warm water irrigator (3 temperature model)
  • Heated or non-heated rigid telescope holders
  • Flexible scope holder
  • Cautery power sockets
  • Low voltage power source
  • Examination microscope
  • HD video endoscopy imaging system with HD video
  • 22” HD LED monitor
  • LED stroboscope (doubles as light source for endoscopes)
  • 100 W coagulator (mono and bipolar modes)
  • Rhinomanometer
  • Tympanometer with EFT function
  • Sinus echography
  • Mirror preheater rack for up to 60 mirrors
  • Hot air mirror heater (automatically switches off after 3 seconds)

A conveniently positioned USB port allows the quick transfer of images and videos to USB data storage devices.

Micronomic Combi

Micronomic 50 metal mobile treatment unit, standard equipped with a suction system and cold light system. Due to its compact dimensions, this treatment unit is ideal for use at the ENT clinic, in the outpatient clinic and for emergency care.

  • 2 drawers for storage
  • – Aluminum inserts for instruments
  • – Garbage bin
  • – 2x 230V socket
  • – Suction system
  • – Built-in light source

Entermed Patient Chair

The fully automatic Entermed patient chair is a comfortable doctor and patient-friendly chair. The 300 degree rotatable seat is smooth to operate and offers a lot of freedom of movement. The chair is automatically adjustable in height (from 54 to 74 cm) and can be loaded up to more than 150 kg.

Easy operation

In addition to the well-designed foot pedal, the Entermed patient chair can be operated using the control panels on the side. The side controls have buttons on one side where pre-programmed positions can be selected. This is easy to program yourself.

Synchronized back and leg support

The backrest and leg rest are perfectly synchronized, making the positions comfortable for the patient. The positions range from completely horizontal to a neat upright position.

Stroboscopes

Best value for stroboscopy
  • High power LED stroboscope.
  • Strobe-camera combination (Procam camera optional).
  • Full range LED strobe (62 to 1200 Hz).
  • Automatic transition light from continuous to strobe mode via patient phonation.
  • Contact microphone (air optional).
  • Affordable compact and portable system.
  • Touch screen control panel.
  • Operating footswitch.
STROBOLIGHT
  • Xenon 180 W Stroboscope.
  • Automatic transition light from continuous to strobe mode via patient phonation.
  • One xenon bulb for both continuous and strobe modes.
  • Contact microphone, automatic voice detection and synchronization with base frequency and manual mode.
  • Full footswitch operation.
  • Rotary turret for all FO cables.
  • Amplified audio output.
RHYNO Soft Rhinomanometer
  • Computerized RHYNO Soft rhinomanometer.
  • Compact CCU connected via USB to a computer using Windows.
  • Automatic calculation of air flow resistance, respiratory frequency, maximum pressure and flow inhalation and exhalation peaks.
  • Flow/pressure graph.
  • Highly accurate.
  • Clear reports and elegantly presented.
Videonystagmograph
  • Compact CCU connected via USB to a computer using Windows.
  • Accurate personalized clinical file with clear and elegantly presented reports.
  • Light weight goggles with two lateral IR cameras with magnetic cover.
  • Caloric, postural and optokinetic tests can be performed by means of user-friendly software.
  • Our advanced software automatically diagrams the Claussen butterfly, the Hallpike test, the FREYSS Graphic, the labyrinth response, and the phase/time speed.
  • Postural and optokinetic tests: the software prepares a summary of vestibular and directional domain, latency, gain, relative amplitude and phase.
  • Visual stimulation tests can be performed using our VGA OPK, with a standard computer monitor (optional).

Endocameras / Light Sources

PROCAM SD
  • High Resolution one CCD camera, 1 chip, PAL 625 lines / NTSC 525 lines.
  • Ergonomic head with 3 controls:
  • White balance.
  • Windows function (two levels).
  • Anti-moiré function (two levels).
  • Less than 1-lux sensitivity.
  • Ideal for the office, affordable.
  • Great image quality.
PROCAM HD
  • Full high definition video-camera 1920 x 1080p.
  • Excellent color reproduction, sharp images and superior depth perception.
  • Ergonomic, lightweight, cool and compact.
  • 2 function keys on camera head for controlling.
  • Zoom.
  • Brightness.
  • Automatic White balance with memory function.
  • High sensitivity.
  • 6 pre loaded applications: Sinuscopy & Otoscopy, Laryngoscopy, Fiberscope, Laparoscopy, Cystoscopy & Hysteroscopy, Arthroscopy.
EVERLUX UNIVERSAL
  • Portable and compact light source.
  • High Power LED.
  • 50,000 hours life LED. Cold, white, high intensity light.
  • Electronic dimmer.
  • Ideal for all endoscopy procedures.
  • Universal connection for all type of FO cables.
EVERLUX
  • Portable and compact light source.
  • High power LED.
  • 50,000 hours life LED. Cold, white, high intensity light
  • Electronic dimmer.
  • Ideal for all endoscopy procedures.
  • Individual connection for most FO Cables (Storz, Olympus, Wolf type).
XENOLUX 180
  • Powerful 180 watts Xenon light source.
  • High intensity light and deep illumination. Rotary turret for all type of FO cables

Rigid and Flexible Endoscopes

Endoscopes

We offer exclusive design, excellent quality and cost effective endoscopes. Outstanding image quality. Exceptional luminosity and brightness. Storz / Wolf and ACMI connections.

FEATURE SINUSCOPES SINUSCOPES OTOSCOPES LARYNGOSCOPES FLEXIBLE SCOPE
Diameter 3.0mm 4.0mm 3.0mm 6.0mm | 8.0mm X
Working Length Approx. 140mm Approx. 175mm 100mm |140mm Approx. 175mm X
Direction of View 0° 30° 70° 0° 30° 45° 70° 0° 30° 70° X
Field of View X X X X 85°
Depth of Field X X X X 2,5 – 50mm
Outer Ø insertion/td> X X X X 3,4mm
Outer Ø distal end X X X X 3,4mm
Range of distal tip X X X X up 130° down 130°

RECORDING DEVICES

Record and document important images & videos from your endoscopic exams, procedures and surgeries.

Endodigi is a family of digital video/image recorders including software and hardware systems, designed to work with real time video High Definition (HD) or Standard Definition (SD).

View live video from your camera while recording images and audio.

Endodigi is simple enough to work seamlessly in your clinic and powerful enough to provide all the documentation needs of any practice capturing media files.

Endodigi SD (Standard definition)
  • Connects USB to computer
  • Wired or wireless foot control. Composite video in x 3
  • Composite video out x 1
Endodigi HD (High definition
  • Connects USB to computer.
  • HDMI input.
Endodigi Driver
  • The easiest and cost-effective recorder
  • No computer needed.
  • Wired or wireless foot control. Inputs: SD video /HD video / 3D video.
  • USB out: pen drive / external hard drive.

AC 40 Clinical Audiometer

SPECIFICATION
Model AC 40
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main Unit (AC 40)
  • Gooseneck 1059 Microphone
  • DD45 Audiometric Headset
  • B81 Bone Conductor Headset
  • APS3 Patient Response Switch
  • Power Cable
  • Monitor Headset with Boom
  • HDA300 Phone headset for HF
  • User Manual
  • Diagnostic Suite Software
Optional Part
  • TDH39AA with Amplivox Headset
  • DD450 Audiometric Headset
  • DD45 with Peltor Headset
  • B71 Bone Conductor
  • Ear tone 5A 10 ohms & 3A 10 ohms
  • IP 30 Insert Phone 10 ohms
  • Talk Back Microphone
  • CIR 33 Insert Earphone Kit for Masking or Monitoring
  • Amplivox Audiocups, Noise Reducing Headset
  • Sound Field Speakers SP90 (with External Power amp)
  • AP12 Power Amplifier 2×12 watt
  • AP70 Power Amplifier 2×70 watt
  • Cable USB 2m
  • OtoAccess™ database
Available Tests Basic License Extended License
Basic Audiometry X X
Bekesy X X
SISI X X
Langenbeck X X
Stenger X X
Modified Hughson Westlake X X
ABLB X X
Speech Testing with Mic/CD X X
Weber X X
Build in Wave Files X X
Binaural Speech X X
Hearing Loss Stimulator (HLS) X X
Tone Decay X X
Pediatric Noise X
MLD X
Multi Frequency X
Free Field Power (4×20W) X X
MHA X X
QuickSIN Optional Optional
TEN Test Optional X
High Frequency (HF) X X
Free field Lineout X X
Hybrid Mode – PC Control Mode Optional Optional
Sync Mode – Audiogram Transfer Optional Optional
TECHNICAL SPECIFICATION
Power Supply 240V / 0.4A 50 Hz
Weight 7.9kg / 17.4lb
Dimensions (L×W×H) 522×366×98 cm / 20.6×14.4×3.9 inch
Display 8.4 inch high resolution color display 800×600 pixel
Compatible Software Diagnostic Suit – Noah OtoAccess XML Compatible
Warm Up Time Approximately 1 minute
Patient Response Switch Two push Button
Operation Environment Temperature: 15 – 35 °∁
Relative Humidity: 30 – 90 %
Ambient Pressure: 98 – 108 kPa
Monitor Real stereo output through build in speaker or through external earphone or assist monitor
Stimuli Tone 125-20000Hz separated in two ranges 125-8000Hz and 8000-20000Hz.
Warble Tone 1-10 Hz sine +/- 5% modulation
Pediatric Noise A special narrowband noise stimulus. The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz and up is fix 8%,
Wave file 44100Hz sampling, 16 bits, 2 channels
Masking Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. IEC 60645-1 2012, 5/12 Octave filter with the same center frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise. IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB
Presentation Manual or Reverse. Single or multiple pulses.
Frequency Range 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected
External Signal Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU.
Free Field output (non-powered) Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter)
Intensity Available Intensity Steps is 1, 2 or 5dB Extended range function: If not activated, the Air Conduction output will be limited to 20 dB below maximum output
Speech Frequency Response
Frequency (Hz) Linear [dB]. FFequv [dB]
Ext. sign Int. sign Ext. sign Int. sign
TDH 39 125-250 +0/-2 +0/-2 +0/-8 +0/-8
250-4000 +2/-2 +2/-1 +2/-2 +2/-2
4000-6300 +1/-0 +1/-0 +1/-0 +1/-0
DD45 125-250 +0/-2 +1/-0 +0/-8 +0/-7
250-4000 +1/-1 +1/-1 +2/-2 +2/-3
4000-6300 +0/-2 +0/-2 +1/-1 +1/-1
E.A.R Tone 3A 250-4000 +2/-3 +4/-1 Non-linear
IP30 250-4000 +2/-3 +4/-1 Non-linear
250-4000 +12/-12 +12/-12 Non-linear
Internal Storage 1000 clients and 50.000 sessions/measurements/audiograms (may depend on session type/size)
External Devices (USB) Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers)
Patient Communication Talk forward and talk back
HDMI output Provides a copy of the built-in screen in HDMI format 800×600 resolution
Data Connections (sockets) 4 x USB A 1 x USB B for PC connection (compatible with USB 1.1 and later) 1 x LAN Ethernet (not used)
Input Specifications TB 212 uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm
Mic.2 212 uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm
CD1/2 16mVrms at max. gain for 0dB reading Input impedance : 47KOhm
TF (side panel) 212uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm
TF (front panel) 212uVrms at max. gain for 0dB reading Input impedance : 3.2KOhm
Wave files Plays wave file from internal SD card
Output Specifications FF 1/2/3/4 Line output 7Vrms at 2KOhms load 60-20000Hz -3dB
FF 1 / 2 / 3 / 4 – powered 4x20W (only 2x20W can be used by software at the moment)
Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB
Ins. Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB
HF Left & Right 7Vrms at 10 Ohms load 60-20000Hz -3dB
HLS 7Vrms at 10 Ohms load 60-20000Hz -3dB
Bone 1+2 7Vrms at 10 Ohms load 60-20000Hz -3dB
Ins. Mask 7Vrms at 10 Ohms load 60-20000Hz -3dB
Monitor headset (side panel) 2x 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load 60-20000Hz -3dB
Assist Mon. Max.3.5Vrms. by 8 Ω load 70Hz-20kHz ±3dB

AD 528 Clinical Audiometer

SPECIFICATION
Model AD528
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main Unit (AD 528)
  • Power supply
  • Audiometric headset
  • Bone conductor
  • Patient response
  • Instructions for use
Optional Part
  • Audiometric headset DD450/DD45
  • Insert masking transducer
  • Monitor headset
  • Talk back
  • Free field speakers
  • Printer
  • Diagnostic software
  • OtoAccess™ database
Available Tests Basic License Extended License
Air, Bone and Free-field X X
Speech: CD,MP3, Microphone or Wave X X
Stenger X X
Modified Hughson Westlake X X
ABLB X
SISI X
Békésy X
Langenbeck X
Weber X
Speech in noise and binaural speech) X
Sync license for integration with NOAH, local EMR systems or OtoAccess X
TECHNICAL SPECIFICATION
Power Supply 240V / 0.4A 50 Hz
Weight 1.5kg / 3.3lb
Dimensions (L×W×H) 11×28×36 cm / 4.3×11×14 inch
Display 5.0 inch high resolution color display 480×272 pixel
Compatible Software Diagnostic Suit – Noah OtoAccess XML Compatible
Internal Battery 230mAh, Li
PC Control (USB) Input/output for communication
Operation Environment Temperature: 15 – 35 °∁
Relative Humidity: 30 – 90 %
Ambient Pressure: 98 – 108 kPa
Printer (Optional) HM-E300 Printer Language: HP PLC3 / HP PLC3 GUI
Patient Response One handheld push button
Patient communication Talk forward(TF) and Talk back (TB)
Monitor Output through build in speaker, monitor headset or speaker
Stimuli Tone 125-8000Hz
Warble Tone 1-10 Hz sine +/- 5% modulation
Wave file 44100Hz sampling, 16 bits, 2 channels
Masking Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. Narrow band noise: IEC 60645-1 2017, 5/12 Octave filter with the same center frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise: IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB
Presentation Manual or Reverse. Single or multiple pulses.
Frequency Range 125Hz to 8kHz
Free Field output (non-powered) Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter)
Intensity Available Intensity Steps is 1, 2 or 5dB
Speech Frequency Response
Frequency (Hz) Linear [dB]. FFequv [dB]
Ext. sign Int. sign Ext. sign Int. sign
DD45 125-250 +0/-2 +1/-0 +0/-8 +0/-7
250-4000 +1/-1 +1/-1 +2/-2 +2/-3
4000-6300 +0/-2 +0/-2 +1/-1 +1/-1
IP30 250-4000 +2/-3 +4/-1 Non-linear
250-4000 +12/-12 +12/-12 Non-linear
Internal Storage 50,000 sessions (500 clients, 100 sessions/client)
External Devices (USB) Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers)
External Signal Speech replaying equipment connected to the aux input must have a signal to noise ratio of 45dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0dB VU
Microphone (Live speech) The microphone of the MTH400m is used for live speech. Microphone gain must be adjusted to 0VU prior to use.

AD226 Diagnostic Audiometer

SPECIFICATION
Model AD226
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main Unit
  • DD45 Audiometric headset
  • B71 Bone conductor
  • APS3 Patient response button
  • Power cable
  • Diagnostic Suit Software
  • Operation manual
Optional Part
  • OtoAccess database
  • 21925 Amplivox audiocups, noise reducing headset
  • Carrying case
  • EARTone3A Audiometric insert phones
  • TDH39 & DD45 Audiometric headset
  • CIR33 Insert earphone set for masking or monitoring
  • IP30 Insert phones
  • P3100 (Pediatric headband)
Available Tests
  • Air and bone conduction
  • Masking
  • Stenger
  • ABLB
  • Hughson Westlake (auto testing)
Extended License
  • Langenbeck (tone in noise)
  • SISI
  • Békésy
TECHNICAL SPECIFICATION
Patient Response switch One push button
Patient communication Talk Forward (TF)
Input Tone, Warble Tone +5%, 5Hz (true sine wave frequency modulation).
Output Left, Right, Bone L+R, Insert Phones, Insert Masking
Dimensions (L×W×H) 30x23x9cm / 12x9x4 inches.
Weight 1.3kg / 2.9lb
Power Supply 5VDC max 1.6A UE10 type only
Batteries 4×1.5V/1.2V Alkaline/NiMH Type AA Note: When the instrument is battery operated the maximum stimuli output level is reduced 20dB
Operation environment Temperature Temperature: 15-35°C Relative Humidity: 30-90% Non-condensing Ambient pressure: 98-104 kPa
Warm Up Time Approximately 1 Minute
Internal storage 500 Patient
Data Connections (sockets) for connection of accessories 1 x USB A for keyboard or printer 1 x USB B for PC connection (compatible with USB 1.1 and later)
External devices (USB) Standard PC keyboard (for data entry) Supported printers: Please contact distributer for a list of approved PC printers
Display 4,3” (480×272) TFT color display
Compatible software Diagnostic Suite – Noah OtoAccess and XML compatible
Stimuli Tone 125-8000Hz
Warble Tone 5Hz sine +/-% modulation
Masking (Narrow band noise) IEC 60645-1 2012, 5/12 Octave filter with the same center frequency resolution as pure Tone Synchronous masking: Locks channel 2 attenuator to channel 1 attenuator
Presentation Manual or Reverse. Single pulse. Multiple pulses 50-5000 msec. on/off
Intensity AC: -10 to 120 dB HL BC: -10 to 80 dB Available Intensity Steps is 1, 2 or 5dB Extended range function: If not activated, the Air Conduction output will be limited to 20 dB below maximum output Extended range only available when mains powered
Frequency range 125Hz to 8kHz. (125Hz, 250Hz, 500 Hz, 750Hz, 1500Hz or 8kHz may freely be deselected)

AD629 Diagnostics Audiometer

SPECIFICATION
Model AD629
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main Unit
  • DD45 Audiometric Headset
  • B71 Bone Conductor Headset
  • APS3 Patient Response Switch
  • Power Cable
  • User Manual
Optional Part
  • Diagnostic Suite software
  • OtoAccess database
  • 21925 Amplivox audiocups, noise reducing headset
  • Carrying case
  • EARTone3A/5A Audiometric insert phones
  • IP30 Audiometric insert phones
  • HDA300 Audiometric headset with double mono 6.3mm jack
  • TDH39 Audiometric headset
  • CIR33 Insert earphone set for masking or monitoring
  • DD450 Audiometric headset
  • Talk back microphone
  • Sound field speakers SP90
  • AP12 Power Amplifier 2×12 Watt
Available Tests Basic License Extended License
Basic Audiometry X X
ABLB X X
SISI X X
Speech X X
Stenger X X
Modified Hughson Westlake X X
Weber X X
Quick SIN (Optional) X X
TEN Test (Optional) X X
High Frequency (Optional) X X
Bekesy X
Langenbeck (tone in noise) X
Binaural speech X
Hearing loss simulator X
MHA X
TECHNICAL SPECIFICATION
Power Supply 240V / 1.5A
Weight 3.3kg / 6.3lb
Dimensions (L×W×H) 36.5 x 29.5 x 6.5 cm / 14.4 x 11.6 x 2.6 inches
Display 5,7 inch
Compatible Software Diagnostic Suit – Noah OtoAccess
Warm Up Time Approximately 1 minute
Patient Response Switch Two push Button
Operation Environment Temperature: 15 – 35 °∁
Relative Humidity: 30 – 90 %
Ambient Pressure: 98 – 108 kPa
Monitor Output through built-in speaker or through external earphone or speaker.
Stimuli Tone 125-8000Hz. Resolution 1/2-1/24 octave
Warble Tone 1-10 Hz sine +/- 5% modulation
Wave file 44100Hz sampling, 16 bits, 2 channels
Masking Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation.
Presentation Manual or Reverse. Single or multiple pulses
Frequency Range 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected
External Signal Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU.
Free Field output (non-powered) Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter)
Internal Storage 250 patients and unlimited sessions/measurements/audiograms
External Devices (USB) Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers)
Patient Communication Talk forward and talk back

AA222 Middle Ear Analyzer & Audiometer

SPECIFICATION
Model AA222
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main Unit (AA222)
  • Clinical or diagnostic Probe
  • Contralateral Headphone
  • DD45 Audiometric Headset
  • Monitor Headset
  • B71 Bone Conductor Headset
  • APS3 Patient Response Switch
  • Power Cable
  • User Manual
  • Daily Calibration Cavity
  • Floss kit
  • Assortment bag BET55
Optional Part
  • Printer Kit including MTP III Printer
  • CAT50 Calibration Cavities
  • IP 30 / CIR 33 Insert Phone
  • TDH39 Headphone
  • HDA 300/280 Audiometric Headset
  • Talk Back Microphone
  • Ear tone 5A 10 ohms & 3A 10 ohms
  • Amplivox Audiocups, Noise Reducing Headset
  • Free Field Speakers
  • Wall Mount
  • Diagnostic Software
  • OtoAccess database
Available Tests Basic License Extended License
Basic Audiometry X X
ABLB – Fowler X X
SISI X X
Speech X X
Stenger X X
Auto Hughson Westlake X X
Speech Ch2On X
Speech in Noise X X
Weber X X
Quick SIN Optional Optional
Tymp 226Hz X X
Ipsi Lateral Reflex X X
Contra Lateral Reflex X X
ETF 1 test non-perforated tympanic membrane X X
ETF 2 test perforated tympanic membrane X X
Reflex decay X X
Tymp 678, 800 & 1000Hz X
Manual tympanometry X
ETF 3 patulous tympanic membrane X
Reflex latency X
TECHNICAL SPECIFICATION
Power Supply 240V / 1.5A
Weight 3.1kg / 6.8lb
Dimensions (L×W×H) 9×33×44 cm / 3.5×13×17.3 inch
Compatible Software Diagnostic Suit – Noah OtoAccess
Warm Up Time Approximately 1 minute
Patient Response Switch Two push Button
Operation Environment Temperature: 15 – 35 °∁
Relative Humidity: 30 – 90 %
Ambient Pressure: 98 – 108 kPa
Monitor Output through built-in speaker or through external earphone or speaker
Audiometry Measure System
Stimuli Tone 125-8000Hz. Resolution 1/2-1/24 octave.
Warble Tone 1-10 Hz sine +/- 5% modulation
Pediatric Noise A special narrowband noise stimulus. The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz and up is fix 8%,
Wave file 44100Hz sampling, 16 bits, 2 channels
Masking Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation.
Presentation Manual or Reverse. Single or multiple pulses.
Frequency Range 125Hz to 8kHz (Optional High Frequency: 8 kHz to 20 kHz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected
External Signal Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 dB or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dBVU.
Free Field output (non-powered) Power Amplifier and Loud Speaker (With an input of 7 Vrms – Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 dB in a distance of 1 meter)
Internal Storage 500 patients and unlimited sessions/measurements/audiograms
External Devices (USB) Standard PC mouse and Keyboard (for data entry) Supported printers (Please contact distributor for a list of approved printers)
Patient Communication Talk forward and talk back
Impedance Measuring System
Probe tone Frequency level 226 Hz, 678 Hz, 800 Hz, 1000 Hz; pure tones; ±1% 85 dB SPL (≈ 69 dB HL) ±1.5 dB
Air pressure Control: Indicator: Range: Pressure limitation: Pump speed: Automatic. Measured value is displayed on the graphical display. -600 to +400 daPa. ±5% -750 daPa and +550 daPa. Automatic, Fast 300 daPa/s, Medium 200 daPa/s, Slow 100 daPa/s, Very slow 50 daPa/s.
Compliance Range 0.1 to 8.0 ml at 226 Hz probe tone (Ear volume: 0.1 to 8.0 ml) and 0.1 to 15 mmho at 678, 800 and 1000 Hz probe tone. All ±5%
Test Types Tympanometry Automatic, where the start and stop pressure can be user programmed in the setup function. Manual control of all functions
Eustachian tube function 1 – Non perforated eardrum Williams test
Eustachian tube function 2 – Perforated eardrum Toynbee test
Eustachian tube function 3 – Patulous Eustachian tube Continuous sensitive impedance measurement
Reflex Function
Signal Sources Tone – Contra, Reflex: THD: 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz, Wide Band, High and Low pass. Less than 5 until 110 dB, 5 % above 110 dB (supra-aural headphones), less than 5 % until 110 dB, 10 % above 110 dB (insert earphones or probe).
Tone – Ipsi, Reflex 500, 1000, 2000, 3000, 4000 Hz wide band, high and low pass.
NB noise – Contra, Reflex 250, 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz
NB noise – Ipsi, Reflex 1000, 2000, 3000, 4000 Hz
Stimulus duration 750 ms
Reflex Acceptance Adjustable between 2 % and 6 %, or 0.05 – 0.15 ml change of ear canal volume
Intervals Down to 1 dB step size
Intensity max 90, 100, 120 dB HL
Outputs Contra Earphone TDH39 earphone, DD45 earphone, CIR insert and/or EARtone 3A insert, IP30 for Reflex measurements
Ipsi Earphone Probe earphone incorporated in the probe system for Reflex measurements
Probe connection Connection of the electrical and air system to the probe
Test types Manual Reflex Manual control of all functions
Automated Reflex Single intensities Reflex growth
Reflex Decay Automatic, 10 dB above threshold and manually controlled with stimulus durations of 10 s.
Reflex Latency Automated, first 300 ms from stimulus start

Affinity 2.0 Hearing Aid Analyser

SPECIFICATION
Model Affinity 2.0
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
AC440 Module
  • Affinity2.0 AC440 CD
  • OtoAccess™ database CD
  • TDH39 Audiometric headset or DD45 Audiometric headset
  • MTH400 Headset
  • EMS400 Talk back microphone *B81 Bone conductor
  • APS3 Patient response button *Standard USB cable
  • Power cable 120 or 230V
  • Mouse pad
  • Instructions for Use document
REM 440 Module
  • Affinity2.0 REM440 CD
  • OtoAccess™ database CD
  • IHM60 In-situ headset with probe microphone and reference microphone (double)
  • Probe tubes, 36 pcs.
  • Standard USB cable
  • Power cable 120 or 230V *Mouse pad
  • Instructions for Use document
HIT 440 Module
  • Affinity2.0 HIT440 CD
  • OtoAccess™ database CD
  • 2cc coupler with microphone and adaptors for ITE, BTE and Body Style HA
  • Coupler seal wax
  • Reference microphone
  • Standard USB cable
  • Power cable 120 or 230V
  • Mouse pad
  • Additional Information and Instructions for Use
Optional Parts:
AC440 Module
  • DAK70 Audiometer keyboard with live voice mic.
  • Earphone 3A insert earphones (5As may be substituted)
  • IP30 insert earphones
  • B71 Bone Conductor
  • ACC60 Affinity2.0 carrying case
  • CIR22 Insert masking earphones
  • Audiocup enclosures
  • Peltor noise excluding headset
  • HDA280 Audiometric headset
  • HDA300 Audiometric headset
  • KOSS R80 high frequency headset
  • AP70 Power amplifier 2×70 Watt
  • SP90 Loudspeaker
  • SP85A Loudspeaker
  • SP90A Loudspeaker
  • AFC8 Sound cabin installation panel
  • USB 1.1 isolation extension cable
REM 440 Module
  • SPL60 Transducer kit for RECD measurement including probes and eartips
  • BET60 Box with eartips for for RECD measurement
  • Calibration adaptor for in-situ reference
  • VSP440 Visible Speech Mapping module
  • Optical USB 1.1 isolation extension cable
  • ACC60 Affinity2.0 carrying case *Coupler microphone extension cable
HIT 440 Module
  • Battery adapters BAA675, BAA13, BAA312, BAA10, BAA5
  • Couplers 1.2CC and 0.6CC: ITE, BTE, Ear simulator
  • TBS25M External test chamber incl. cables
  • ACC60 Affinity2.0 carrying case
  • Calibration adaptor
  • Optical USB 1.1 isolation extension cable
  • SKS10 Skull Simulator with power supply
Tests: (some are optional)
AC440 Module
  • Air Conduction Audiometry
  • Bone Conduction Audiometry
  • Masking 27
  • Speech Audiometry
  • Masking Level Difference
  • Weber
  • Knaster
  • ABLB/Fowler
  • Stenger Test
  • Tone Decay ANL Test
  • SIQ Test
  • SIN Test
  • High Frequency Audiometry *Multi Frequency Audiometry
  • Speech from hard drive
  • Master Hearing Aid (MHA)
  • Short Increment Sensitivity Index(SISI)
  • Hearing Loss Simulation (HLS)
  • QuickSIN
  • TEN Test
  • Loudness Scaling
REM 440 Module
  • REUR/REUG Measurements
  • REAR/REAG Measurements
  • REIG Measurements
  • RECD Measurements
  • REOR/REOG Measurement
  • Measuring Input/Output
  • Directionality Measurements
  • Binaural REM Measurements
HIT 440 Module
  • Frequency Response
  • Gain Curve Harmonic
  • Distortion Intermodulation
  • Distortion Attack/Recovery
  • Time Battery Current
  • Drain/Battery Life Time
  • Equivalent Input Noise
  • Reference Test Gain
  • Microphone Directionality
  • Single Frequency
  • Response/Gain/Input/Output
  • Delay 289 OSPL90 290
TECHNICAL SPECIFICATION
Dimensions (LxWxH) 42 x 38 x 14 cm / 16.5 x 15 x 5.5 inches
Weight 5.5 kg / 12.1 lbs
Power supply 100-240 V~, 50-60Hz
Power Consumption 195VA
Operation environment Temperature: 15-35°C Re. Humidity: 30-90% Non condensing
Transport and storage Transport temperature: -20-50°C Storage temperature: 0-50°C Re. Humidity: 10-95% Non condensing
Data Connections USB/PC USB B socket for connection to PC (compatible with USB 1.1 and later)
USB USB A socket for connection of other USB devices (Internal USB 1.1 hub)
Keyb. Serial Peripheral Interface Bus (SPI interface)
Internal test box Built in test box holds telecoil drive as well as special dual speaker set for checking directional microphone function
Supported Systems Windows® 7 (32 and 64 bit) Windows®8 (32 and 64 bit) Windows® 10 (32 and 64 bit)
PC requirements 2 GHz Intel Core 2 Duo CPU 2GB Ram
1.5 GB available disk space1024x768 resolution (1280×1024 or higher recommended) Hardware accelerated DirectX/Direct3D graphics card. One or more USB ports, version 1.1 or higher. DVD-Rom drive
Display 1024×768 resolution (1280×1024 or higher recommended) Hardware accelerated DirectX/Direct3D graphics card
Disc Space 1.5 GB available disk space
Operative System Windows® 7, Windows ® 8, Windows® 10
Compatible software Noah 3.7, Noah 4,, OtoAccessTM and XML compatible Affinity2.0 / Equinox2.0 Suite
Input Specifications Talk Back 330μVrms at max. input gain for 0dB VU-reading Input impedance : 47.5KΩ
Mic. 1/TF & Mic. 2
Pat. Resp. L & R Switches 3.3V to the logic input. (The switch current is 33μA)
Inp. Aux. 1 & 2 20mVrms at max. input gain for 0dB VU-reading Input impedance : 15KΩ
TB Coupler
TB Coupler – internal TB
(Affinity2.0 .0 only) Insitu L & R – Probe mic.
CD1 & CD2 10mVrms at max input gain for 0dB VU-reading Input impedance : 10kΩ
TB Ref. 7mVrms at max. input gain for 0dB VU-reading Input impedance : 4,3KΩ
TB Ref – internal TB
(Affinity2.0 .0 only) Insitu L & R – Ref. mic
Ref.Mic./Ext. Not in use
Coupler/Ext.
Wave files Plays wave file from hard disk drive
Output Specifications FF1 / FF2 (Terminal Block) Up to 12.6Vrms by 8 Ω load 70Hz-20kHz ±3dB
TB Lsp.
FF1/ FF2 Up to 7Vrms by 600Ω load 70Hz-20kHz ±3dB
Sp 1, Sp 2, Sp 3, Sp 4
Left, Right Up to 7.0Vrms by 10Ω load 70Hz-20kHz ±3dB
Ins. Left, Ins. Right
Bone
Ins. Mask.
HF/HLS
Insitu L, Insitu R
Monitor, Ass. Mon. Max.3.5Vrms. by 8 Ω load

Eclipse

SPECIFICATION
Model Eclipse
Manufacturer Interacoustics
Country of Origin Denmark
Included Parts
  • Main unit (Eclipse)
  • EP 25 module
  • Two channel evoked potential system that allows for recording ABRs, middle and late latency potential
  • VEMP module
  • Assists in the assessment of vestibular function.
  • TEOAE module
  • Audiologic evaluation and documentation of ear disorders using transient evoked otoacoustics emissions
  • DPOAE module
  • Audiologic evaluation and documentation of ear disorders using distortion product otoacoustics emissions
  • ASSR module
  • Analysis of human physiological data for the diagnosis of auditory and hearing related function
  • ABRIS module
  • Audiologic evaluation and documentation of ear and nerve disorders using auditory evoked potentials from the inner ear, the auditory nerve and the brainstem. Target population is newborns
  • Power cable
  • USB cable
  • IP 30 insert phones including ear tips
  • Pediatric starter kit
  • ECochG starter kit
  • Disposable electrodes
  • NuPrep gel
  • Alcohol pads
  • Jumper cable
  • ETB standard surface electrode with buttons
  • ETSE tab surface electrode kit
  • OAE probe
  • OtoAccess software
  • Instruction for use
  • Additional information manual
Optional Part
  • DD45 Headphones
  • B81 Bone conductor
  • Sanibel disposables and accessories
Test types / Functionality
  • Click stimulus
  • Broadband CE-Chirp LS stimulus
  • Narrowband CE-Chirps LS stimulus
  • Tone burst stimuli (0.25-8kHz)
  • Recording window
  • ABR
  • Rate study
  • ECochG
  • MLR
  • ALR
  • MMN/P300
  • eABR
  • cVEMP/oVEMP
  • EMG controlled stimulus/recording
  • EMG scaling (rectification)
  • Patient EMG monitor / tone
TECHNICAL SPECIFICATION
Power Supply Input Volt: 100-240VAC / 50/60Hz Consumption: 26W (0.3A max)
Weight 2.5kg / 5.5lb including accessories
Dimensions (L×W×H) 28×32×5.5 cm / 11×12.6×2.2 inch
Construction Metal cabinet
Compatible Software Diagnostic Suit – Noah OtoAccess
Display XML Compatible
Warm Up Time 10 minutes at room temperature
PC Control USB 1.1 or 2.0 for input/output for computer communication Eclipse is fully operated from a PC
Operation Environment Temperature: 15 – 35 °∁
Relative Humidity: 30 – 90 %
Ambient Pressure: 98 – 104 kPa
EP 25 / VEMP Specifications
EPA Preamplifier Two channels standard EPA4 Cable Collector (4 electrodes). Standard 50 cm. Option: 5cm or 290 cm
One Channel (optional) EPA3 Cable Collector (3 electrodes). 50 cm
Gain: 80 dB/60 dB
Frequency response: 0,5 – 5000 Hz
CMR Ratio: Minimum >118 dB. Typical 130 dB < 100 Hz
Radio frequency Typically 25 dB improvement over previous available
Max input offset desig
Input impedance 10 MΩ/ 170 pF
Power from main unit Insulated power supply with 1500 V isolation. The signal is digitally/capacitive insulated
Stimulus: Stimulus rate: 0.1 to 80.1 stimuli per second in steps of 0.1.
Envelopes/Windows : Bartlett, Blackman, Gaussian, Hamming, Hanning, Rectangle and Manual (Rise/Fall and Plateau)
Masking: White noise. Calibrated and presented in SPL.
Transducer: Ear Tone ABR insert phone, calibrated on an IEC 711 coupler.Headphone with independent calibration (optional) Bone conductor (optional)
Level 20 – 135.5 dB peSPL, (-10 – 100 dB nHL) in 1 dB steps
Polarity: Condensation, Rarefaction, Alternating
Click: 100 μs (200Hz -11kHz)
Tone Burst Frequency 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz.
Tone Burst Stimulation Time: Stimulation up to 780 ms
NB CE-Chirp® LS Freq.: 500, 1000, 2000 and 4000 Hz
Broadband CE-Chirp®: 200Hz -11kHz
LS 200Hz -11kHz Relative Masking Level: +30dB to -40 dB relative to stimulus level. The stimulus level ispresented in nHL. The masking level is only presented in SPL, and can therefore not exceed the loudness of the stimulus.
Recording: Analysis Time: -150 ms prior to stimuli and up to 1050 ms dependent).
A/D Resolution 16 bit.
Sampling frequency 30 kHz
Artifact Reject System: Standard voltage based system
Rejection levels: Manual 0.2 – 640 μV input with 0.1uV steps.
Anti-aliasing filter Analog 5kHz, 24 dB / octave
Dots per Trace: 450 displayed.
Low Pass Filter: None or 17 – 12000 Hz depend on the measurement type
High Pass Filter: 0.83 Hz to 500 Hz depending on the measurement type.
DSP Low Pass Filter: 100, 300, 750, 1k, 1,5k, 2k, 3k, 4k, 5k, 7,5k Hz
DSP High Pass FilterDSP High Pass Filter 0.5, 1.0, 3.3, 10, 33, 100 Hz
Display Gain: General Display Gain. Applicable during testing. Single Curve Display Gain. Applicable during testing.
Controlled parameters: Stimuli Rate, Number of stimuli, Polarity, Click, Tone Burst, Stimulus intensity, Number of curves per intensity, Intensity, Soft attenuator, Stimulus ear, Transducer, Masking level, Preliminary filter setting, Recording onset, Automatic next intensity, General Display Gain, Single Curve Display Gain, Baseline, Latency norm, Report templates, Print out, Manual stimulus to familiarization, Talk Forward.
Data collection: Impedance test, Waveform buffer, Curve, Online EEG, Waveforms storage in unlimited storage database
Data Recovery: Lost data due to crash of Windows® will in almost all cases be Available upon re-establishing Windows operation.
TEOAE 25 Specification
Stimulus: Type: Click (Linear or Non-linear)
Bandwidth: 500 – 5500 Hz
Level: 50-90 dB SPL
Level Step: 1 dB SPL
Transducer: Dedicated TEOAE25 probe (Accuracy 0.5 dB)
Recording: Recording: Analysis time: 25 to 32000 samples
Sampling frequency 30 kHz
A/D Resolution 16 bit, 3.7 Hz resolution
Artifact Reject System: 25 – 55 dB SPL or off. Applicable during testing
SNR Criteria 5 individual frequency bands can be set 1-30 dB SPL
Display gain: General Display gain Applicable during testing
DPOAE 20 Specification
Stimulus: Frequency Range: 500-8000 Hz
Frequency Step: 50 Hz
Level: 30-75 dB SPL (70 dB above 6kHz)
Level Step 1 dB SPL
Transducer: Dedicated DPOAE20/TEOAE25 probe
Recording: Analysis time: minimum 2 sec to unlimited test time
A/D Resolution 16 bit, 3.7 Hz resolution
Sampling frequency Sampling frequency
Artifact Reject -30 – 30 dB SPL or off. Applicable during testing
Stimulus Tolerance Adjustable
SNR Criteria Adjustable
Probe check window 256 points frequency response of the ear canal due to a click
DP-Response window 4096 point frequency response
Display gain: General Display gain Applicable during testing
EPA Preamplifier Two channels standard EPA4 Cable Collector (4 electrodes).
One Channel (optional): EPA3 Cable Collector (3 electrodes). 50 cm
Gain: 80 dB/60 dB
Frequency response: 0,5 – 5000 Hz
CMR Ratio: Minimum >118 dB. Typical 130 dB < 100 Hz
Radio frequency immunity: Typically 25 dB improvement over previous available designs
Max input offset voltage 2,5 V
Input impedance: 10 MΩ/ 170 pF
Power from main unit: Insulated power supply with 1500 V isolation. The signal is
Specifications as EPA4 Impedance measurement: Selectable for each electrode
Measurement frequency 33 Hz
Waveform Rectangular
Measurement current 19μA
Range: 0.5 kΩ – 25 kΩ
Stimulus: Stimulus rate: 93 Hz
Level: 30, 35, 40 dBnHL
Click: 100 μs
Recording: Analysis time: 120 seconds
A/D resolution: 16 bit
Sampling frequency 30 kHz
Artifact rejection system Standard voltage based system
Display: Stimulus level and type, Graph view
Security: Password protection of test parameters possible.
Algorithmic Click: 99.99%
Sensitivity Click: ≥ 97%
ABRIS Module Specification
Stimulus type Click
Stimulus rate 93 Hz
Stimulus intensity 30, 35, 40dB nHL
Test time 120 seconds (default)
Test montage mastoid or nape
Test method monaural
User customizable protocols X
Password protection of test parameters X
ASSR Module Specification
Stimulus level 0 – 100 dB nHL
Narrow Band CE-Chirp® stimuli (0.5, 1, 2, 4 kHz) X
Recording time Up to 15 min per curve
Stimulus rate 40 or 90 Hz
Transducer options Headphone, DT48A, Inserts, Bone
nHL to eHL correction factors (Child/Adult) X
Residual noise calculator X
User customizable protocols X
Noah 4 and higher compatibility X